CHNSpec Technology (Zhejiang)Co.,Ltd chnspec@colorspec.cn 86-571-85888707-813
Product Details
Place of Origin: China
Brand Name: CHN spec
Certification: CE
Model Number: DS-36D
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: negotiable
Packaging Details: Carton box with foam package, packing size 66x46x33cm
Delivery Time: 5-7 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000 per month
Camera Positioning: |
Ultra HD Camera(1400dpi) |
Brightness Calibration: |
√(Through The Brightness Calibration Algorithm, The Real Color Of Ultra-dark Samples Is Restored) |
Storage: |
8GB |
Power Source: |
Dc Regulated Power Supply |
Port: |
RS-232、USB、USB-B、Bluetooth |
Language: |
Simplified Chinese, English, Traditional Chinese, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish |
Screen Size: |
7-inch Capacitive Touch Screen |
Accessories: |
Power Adapter, USB Cable, Transmission Fixture, Software U Disk, Black Cavity, White Board, Green Board,30mm Aperture, 18mm Aperture ,11mm Aperture, 6mm Aperture, Support Table,cuvette, |
Automatic Calibration: |
√(Can Greatly Improve The Long-term Repeatability Of The Instrument) |
Sensor: |
Differential Spectrum Engine |
Operating System: |
Android |
Display Content: |
Spectral Data, Spectrogram, Chromaticity Data, Chromaticity Data, Chromaticity Map, Pass/Fail Judgment, Simulation Color, Color Evaluation, Fog, Liquid Chromaticity, Color Bias |
Camera Positioning: |
Ultra HD Camera(1400dpi) |
Brightness Calibration: |
√(Through The Brightness Calibration Algorithm, The Real Color Of Ultra-dark Samples Is Restored) |
Storage: |
8GB |
Power Source: |
Dc Regulated Power Supply |
Port: |
RS-232、USB、USB-B、Bluetooth |
Language: |
Simplified Chinese, English, Traditional Chinese, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish |
Screen Size: |
7-inch Capacitive Touch Screen |
Accessories: |
Power Adapter, USB Cable, Transmission Fixture, Software U Disk, Black Cavity, White Board, Green Board,30mm Aperture, 18mm Aperture ,11mm Aperture, 6mm Aperture, Support Table,cuvette, |
Automatic Calibration: |
√(Can Greatly Improve The Long-term Repeatability Of The Instrument) |
Sensor: |
Differential Spectrum Engine |
Operating System: |
Android |
Display Content: |
Spectral Data, Spectrogram, Chromaticity Data, Chromaticity Data, Chromaticity Map, Pass/Fail Judgment, Simulation Color, Color Evaluation, Fog, Liquid Chromaticity, Color Bias |
Benchtop spectrophotometer
Excellent inter- instrument agreement and repeatability
Color spectrum benchtop spectrophotometer DS-36D adopts self-developed differential spectrum engine to increase light intake by 50% and spectral resolution by 30%. Provide better repeatability, inter-station difference, display performance; The clarity of the camera is increased by 350%, and the color of ultra-dark samples can be truly restored through the self-developed brightness calibration algorithm. The powerful ColorExpert computer data management software supports the simultaneous saving of sample data and images. DS-36D products will play a more outstanding role in quality control management and color matching in various industries such as paint, plastics and textiles.
Benchtop spectrophotometer DS-36D
DS-36D:repeatability0.01,Inter-instrument agreement0.15
· Equipped with two types of lighting sources: pulse xenon lamp and LED
· 37 standard light sources, 40+measurement indicators
·Automatic recognition of four apertures switching
·Temperature and humidity calculation compensation function
·7-inch touch screen, Android operating system
· Provide powerful ColorExpert computer data management software
· Can save data to the cloud and follow the account to prevent loss
· Support PC end export or printing of data test reports
· Support color matching software to provide more formula inspiration and improve color matching efficiency
Differential spectrum engine improves overall measurement performance
The light input of the sensor is increased by 50%, the spectral resolution is increased by 30%, the signal-to-noise ratio is higher, the repeatability, the difference between the instrument, and the data is highly consistent with the data of the standard instrument, the inter-instrument agreement can reach to 0.08, and the repeatability can reach to 0.005. The relevant technologies are protected by Chinese invention patents.
Double optical path design improves repeatability accuracy repeatability accuracy dE*ab≤0.005
The dual optical path design monitors the energy fluctuation of the light source while measuring the sample signal, reduces interference during measurement, obtains higher measurement stability, and improves the measurement repeatability index of the instrument to dE*ab ≤ 0.005. The high standard of measurement speed, accuracy, stability and inter-station difference is guaranteed. The relevant technologies are protected by Chinese invention patents and American invention patents.
Innovative 1nm resolution grating spectroscopy technology
Innovation is the soul of CHNSpec. After nearly 10 years of dedicated research, the grating combined array sensor made by the innovative MEMS process makes the color measurement more accurate on the basis of 1nm spectral resolution, once again leading the industry innovation direction and greatly improving the technical performance of the product. The relevant technologies are protected by Chinese invention patents.
Excellent inter-instrument agreement:dE*ab≤ 0.08,
High repeatability accuracy:dE*ab≤0.005, ensure accurate data transfer between factories
High precision automatic calibration
Advanced automatic calibration technology greatly improves long-term repeatability of instruments. Under constant temperature, the dE*ab of day 1 and day 30 can still reach 0.01. At any temperature change from 0℃ to 40℃, dE*ab can reach less than 0.1.
Technical Parameter
Benchtop spectrophotometer | |||
Model | DS-36D | DS-37D | DS-39D |
Lighting/measurin g conditions |
Reflection: d/8 (diffuse illumination, 8° direction reception) | ||
SCI(Contains specular reflected light)/ SCE(not contain specular reflected light)measure at same time. Compliance standards: CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, DIN5033 Teil7, JIS Z8722 Condition C, ASTM E1164, ASTM-D1003-07 |
|||
Transmission: d/0 (diffuse illumination, vertical reception) | |||
Sensor | Differential spectrum engine | ||
Spectroscopic method |
Concave grating | ||
Integrating sphere diameter |
152mm | ||
Wavelength range | 360nm-780nm | ||
Wavelength interval |
10nm | ||
Half-wave width | 1.6nm | ||
Reflectance measurement range |
0-200%,resolution0.01% | ||
Ultraviolet measurement |
Includes UV, 400nm cutoff, 420nm cutoff, 460nm cutoff | ||
Measuring time | Single mode <2s | ||
Lighting/measurin g calibers |
XLAV Φ25.4mm/Φ30mm;LAVΦ15mm/Φ18mm;MAVΦ8mm/Φ11mm;SAVΦ3mm/Φ6mm Users can customize the calibre, and the calibre switch is automatically recognized Transmission:Φ17mm/Φ25mm |
||
Transmission measurement specification |
Sample height and thickness: height is not limited, thickness ≤50mm | ||
Long-term repeatability |
XLAV chroma value: standard deviation ΔE*ab within 0.1 (0℃-40℃ arbitrary temperature change) XLAV chroma value: standard deviation ΔE*ab 0.01 or less (under constant temperature conditions, the white correction plate is measured every hour within 24 hours) |
||
Repeatability * | ΔE*ab≤0.01, Spectral reflection/transmittance ≤0.1% |
ΔE*ab≤0.005, Spectral reflection/transmittance ≤0.1% |
|
Inter-Instrument Agreement** |
XLAV ΔE*ab 0.18 | XLAV ΔE*ab 0.12 | XLAV ΔE*ab 0.08 |
Standard observer | 2° and 10° | ||
Viewing light source |
A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83,TL84,ID50, ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2 |
||
Language | Simplified Chinese, English, Traditional Chinese, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish |
||
Display content | Spectral data, Spectrogram, chromaticity data, chromaticity Data, chromaticity map, Pass/Fail judgment, Simulation color, Color evaluation, fog, liquid chromaticity, Color bias |
||
Color space | CIE LAB,CIE LUV,LCh,Hunter Lab,Yxy,XYZ,Musell,s-RGB,βxy | ||
Chroma index | WI(ASTM E313-20,ASTM E313-73,CIE,ISO2470/R457,AATCC,Hunter,Taube,Berger Stensby),YI(ASTM D1925,ASTM E313-20,ASTM E313-73),Tint(ASTM E313-20),Isochromatic index Milm, color fastness, color changing fastness,ISO brightness,R457,A density,T density,E density,M density,APHA/Hazen/Pt-Co(platinum-cobalt index),Gardner(Gardner Index),Saybolt(Seibert Index),Astm color, fog, total transmittance, covering power, force, intensity |
||
Color difference formula |
ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc,ΔE*94,ΔE*00,ΔEab(Hunter),555 color tone classification | ||
Storage | 8GB | ||
Screen size | 7-inch capacitive touch screen | ||
Operating system | Android | ||
Power source | Dc regulated power supply | ||
Operating temperature and humidity |
5 ~ 40°C, relative humidity 80%(35°C) below no condensation | ||
Storage temperature and humidity |
-20 ~45°C, relative humidity 80%(35°C) below no condensation | ||
Accessories | Power adapter, USB cable, transmission fixture, software U disk, black cavity, white board, green board,30mm aperture, 18mm aperture ,11mm aperture, 6mm aperture, support table,cuvette, |
||
Optional accessories |
Heating transmission jig (including control circuit), vertical bracket, pneumatic jacking rod (including control circuit), small sample holding accessories, reflection cupping plate (non-removable), fiber test box, film jig, micro transmission jig, rod box, European standard plug, American standard plug |
||
Port | RS-232,USB,USB-B,Bluetooth | ||
Camera positioning |
Ultra HD camera(1400dpi) | ||
Automatic calibration |
√(Can greatly improve the long-term repeatability of the instrument) | ||
Fluorescence calibration |
√(Can automatically adjust the UV intensity, and ensure that the value of the instrument is highly consistent with that of other imported instruments when measuring materials containing fluorescence) |
||
Brightness calibration |
√(Through the brightness calibration algorithm, the real color of ultra-dark samples is restored) | ||
Others | The instrument can be measured sideways, up and down (using accessories); Automatic temperature and humidity compensation function; PC side software save sample image function |
※ After instrument calibration, the white correction plate was measured 30 times at 5-second intervals to measure the standard deviation of the result in XLAV caliber ※※ Based on 23°C, the average value of XLAV aperture measurement of 12 swatches of BCRA Series is measured